Technical Information

Type Series Action Bore size (mm)
Standard JCQ Double acting, Single rod 12,16,20,25,32,40,50,63,80,100
Specifications JCQ, JCDQ
Bore size [mm] 12 16 20 25 32 40 50 63 80 100
Action Double acting, Single rod
Fluid Air
Proof pressure 1.0 MPa
Max. operating pressure 1.0 MPa
Min. operating pressure 0.07 MPa 0.05 MPa
Ambient and fluid 
temperatures
5 to 60°C
Lubrication Not required (Non-lube)
Piston speed 50 to 500 mm/s 50 to 300 mm/s
Cushion Rubber bumper
Allowable kinetic energy [J] 0.022 0.038 0.055 0.09 0.15 0.26 0.46 0.77 1.36 2.27
Rod end thread Female thread
Stroke length tolerance +1.3mm