Technical Information

Analog section
Excitation voltage DC5V±5% Output current:within 90mARatio metric type (Up to six 350Ω load cells can be connected in parallel.)
Signal input range -0.5 to 3.0mV/V,0 to 3.0mV/V (when OIML R76-1-compliant)
Zero adjustment range Automatic adjustment by digital operation-0.2 to 2.0mV/V,0 to 2.0mV/V (when OIML R76-1-compliant)
Span adjustment range Automatic adjustment by digital operation0.3 to 3.0mV/V,0.6 to 3.0mV/V (when OIML R76-1-compliant)
Minimum input sensitivity 0.15μV/count0.5μV/count (when OIML R76-1-compliant)
Accuracy Non-linearity: within 0.01%/FSZero drift: 0.025μV/℃ RTI typGain drift: 1ppm/℃ typ
A/D converter Conversion rate: 300 times/sec.Conversion resolution: 24bit (binary)
Minimum indication resolution 1/10000, 1/6000 (when OIML R76-1-compliant)
Secondary calibration Equivalent input calibration Minimum indication resolution for secondary calibration:1/1000 (ordinary temperature)

 

Setting section
Setting method Settings are made by operating the membrane keys.Also, settings can be made from a host computer through the RS-485 interface.
Memory of set value Calibration value and a part of set value: NOV.RAM (nonvolatile RAM)Other set values: F-RAM (nonvolatile RAM)
Protect of set value Protect can be set by Lock switch and Lock parameter.
Setting items Upper limit/ Lower limit/ Near zero/ Set point 1/ Set point 2/ Compensation/ Over/ Under/ Final/ Comparison inhibit time/ Judging time/ Complete output time/ Compensation feeding time/ Auto free fall compensation regulation/ Weighing function 1/ Weighing function 2/ Tare setting/ Tare display/ Digital low pass filter/ Moving average filter/ MD/ZT period/ ZT range/ Total comparison selection/ Total limit (most significant 4 digits)/ Total limit (least significant 5 digits)/ Count limit/ Weighing function 3/ Key invalid・Lock/ Input selection 1/ Input selection 2/ Output selection 1/ Output selection 2/ Error output selection/ Reserve output selection/ Password/ Bag clamp output time/ Discharging time/ Weighing start time/ AZ times/ Judging times/ Sequence mode 1/ Sequence mode 2/ Filling enhancement value/ Expanded function selection 1/ Expanded function selection 2/ Balance weight value/ Capacity/ Min. scale division/ DZ regulation value/ Display selection 1/ Gravitational acceleration/ Net over/ Gross over/ Display selection 2/ RS-485 I/F setting/ RS-485 Communication type/ RS-485 ID/ Transmission delay time/ Zero calibration/ Span calibration/ Equivalent calibration/ Option display

 

External signal (You can specify whether PNP (Source) type or NPN (Sink) type when order the F701-S.)
Output signals (16) SP1/ SP2/ SP3/ Complete/ Discharge/ Bag clamp/ Error selection 1,2/ Output selection 1 to 6/ Reserve 1,2At signal ON, output transistor ON.* External voltage must be prepared separately by customer.
Input signals (16) Operation permission/ Weighing start/ Stop/ Discharge command/ Manual discharge/ Discharge gate open/ Accumulation clear/ Input selection 1 to 6/ Code 1,2,4Contact (relay, switch etc.) or non-contact (transistor, open collector etc.) can be connected.* External voltage must be prepared separately by customer.
Interface ・ 485: RS-485 communication interface (Select from Modbus-RTU and original format)・ 232: RS-232C communication interface (option)・ BCO: BCD parallel data output interface (sink type) (option)・ BSC: BCD parallel data output interface (source type) (option)・ DAC: D/A converter (option)・ ODN: DeviceNet interface (option)・ PRF: PROFIBUS interface (option) * PROFIBUS-DPV0・ CCL: CC-Link interface (option)

 

Display section
Display 18.5mm in character height, Numerical display on LCD(7 digit)Sub display:7.3mm in character height (14 digit)
Indicated value 5 digit sign: negative display at the highest digit
Accumulation value 9 digit* This can be changed to “Accumulation count (4 digit)”, “Final(5 digit)”, “Code(1 digit)”, “Total discharge count (6 digit)” and “Discharge count (5 digit)”.
Display frequency Select from 1, 2, 5, 10, 20 times/sec.(The system speed is 300 times/sec.)
Capacity 5 digit
Min. scale division Setting allowable in the range of 1 to 50.* Only the following settings are valid when OIML R76-1-compliant:0.001, 0.002, 0.005, 0.010, 0.020, 0.050, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50
Decimal point Select from 0, 0.0, 0.00, 0.000
Over display LOAD: A/D converter input over,OFL1: Net over,OFL2: Capacity +9 scale division,-OFL2: Capacity -over or -20 scale division over,OFL3: Gross over
Center zero A true zero point or the center of each value is displayed.* Only true zero point is displayed when OIML R76-1-compliant.
Status display CLAMP/ SP3/ SP2/ SP1/ HOLD/ COMPL./ ZT/ ZALM/ STAB/ TARE/ NET/ GROSS/ NZ/ D.CHG/ HI LIM/ HI/ GO/ LO/ LO LIM/ CZ/ LOCK

 

General performance
Power supply voltage AC100 to 240V (+10% -15%)(free power source 50/60Hz)
Power consumption 15W max.
Inrush current 2A, 3mSec: AC240V average load condition (cold start at room temperature)
Operating conditions Temperature…Operation -10℃ to +40℃, Storage -20℃ to +85℃Humidity…85% or less (non-condensing)
Dimensions 192(W)×96(H)×140(D) mm (Projections excluded)
Panel cutout dimensions 186 +2 -0(W)×92 +1 -0(H)mm* Installation panel thickness: 1.6 to 3.2mm
Weight Approx. 2kg