Model: PFUW760, PFUW711
PFUW Series – Compatible with various types of liquids and easy to manage remotely.
Model | PFUW760 | PFUW711 | ||
Fluid |
Applicable fluid |
General liquids (Water, Oil, Chemical liquids, etc.) | ||
Fluid temperature range | 0 to 90°C (No freezing or condensation) | |||
Flow | Rated flow range | 0 to 60 L/min (Flow under 0.6 L/min is displayed as 0.0 L/min)∗3 |
0 to 100 L/min (Flow under 1.0 L/min is displayed as 0.0 L/min) |
|
Detection method | Ultrasonic method (Propagation time difference method) | |||
Accuracy | Flow rate accuracy | ±3.0% F.S. | ||
Analog output accuracy | ±3.0% F.S. | |||
Repeatability | ±2.0% F.S. | |||
Temperature characteristics | ±5.0% F.S. (25°C standard) | |||
Analog output |
Output type | Voltage output: Select from 1 to 5 V or 0 to 10 V, Current output: 4 to 20 mA |
||
Impedance | Voltage output |
Output impedance: Approx. 1 kΩ |
||
Current output | Max. load impedance: 600 Ω at power supply voltage of 24 V | |||
External input |
Input type | Input voltage: NPN setting: 0.4 V or less (Reed or Solid state) PNP setting DC (+) -1 V or more |
||
Input mode | Select from accumulated value external reset, peak/ bottom reset, or zero-clear. |
|||
Input time | 30 ms or more | |||
Switch output |
Output type | Select from NPN or PNP open collector. | ||
Output mode | Select from hysteresis, window comparator, accumulated output, accumulated pulse output, error output, or switch output OFF modes. |
|||
Electrical | Power supply voltage | 18 to 30 VDC | ||
Current consumption | 85 mA or less | |||
Display | Display mode | Main screen: Instantaneous flow rate display Sub screen: Select from set flow rate display, accumulated flow rate display, etc. |
||
Display method | LCD, Display color: White/Orange/ Red/Green/Blue, 90/180/270° rotatable, Display values updated 10 times per second |