Stainless steel single point load cell from Unipulse
Model: PW27AP-10KG, PW27AP-20KG
Model | PW27AP-10KG |
PW27AP-20KG |
Rated capacity | 10kg | 20kg |
Rated output | 2.0±0.2mV/V | |
Limit load at 20mm eccentricity | 1000%R.C. | |
Service load at max. 120mm eccentricity | 150%R.C. | |
Maximum safe side overload | 200%R.C. | |
Zero balance | 0±0.1mV/V | |
Non-linearity | 0.0166 typ.%R.O. | |
Hysteresis | 0.0166 typ.%R.O. | |
Compensated temperature range | -10 to +40℃ | |
Safe temperature range | -10 to +70℃ | |
Temperature effect on zero | 0.0140%R.O./10K | |
Temperature effect on span | 0.0175(+20 to +40℃), 0.0117(-10 to +20℃)%R.O./10K | |
Input resistance | 300 to 500Ω | |
Output resistance | 300 to 500Ω | |
Recommended excitation voltage | 1 to 12V | |
Insulation resistance | 1000 MΩ or more | |
Cable | KAB177-3:φ5.4 6 conductor hygiene design cable 3m End treatment 7 leads | |
Load cell material | Stainless steel | |
Deflection at rated | 0.19 mm | 0.18 mm |
Natural frequency | 210kHz | 315kHz |
Maximum off center distance | 150mm | |
Maximum platform size | 400×400mm | |
Weight | 0.8kg | |
Cleaning temperature | Up to 120°C in 10 minutes |
* IP69K load condition: DIN 40050 part 9 compliant