Technical Information

Analog section
Excitation voltage 5 Vdc±5% Output current: within 90mA Ratiometric method(Up to 6 load cells at 350Ω can be connected in parallel.)
Signal input range -0.5 to 3.0mV/V
Zero adjustment range -0.2 to 2.0mV/V (automatic adjustment by digital computation)
Gain adjustment range 0.3 to 3.0mV/V (automatic adjustment by digital computation)
Minimum input sensitivity 0.15μV/count
Accuracy Non-linearity: within 0.01%/FSZero drift: 0.025μV/℃RTI TypGain drift: 1ppm/℃ Typ
A/D converter Speed: 1200, 300 times/sec. (selectable)Resolution: 24bit (binary)
Min. display resolution 1/10000
Theoretical calibration equivalent input calibration (accuracy when theoretical calibration is performed at ambient: 1/1,000)

 

Filter
Low-pass filter When A/D conversion rate is 1200 times/sec: 6, 8, 10, 12, 16, or 20Hz (selectable)When A/D conversion rate is 300 times/sec: 1.5, 2, 2.5, 3, 4, 5Hz (selectable)
Moving average filter 1 to 512 times

 

Display section
Display unit Main display: numerical display (7-digit) with a character height of 18mm by fluorescent display tubeCode (blend): Character height 8mm, numerical display by 7-segment green LED (2-digit)
Weight display 5-digits (signs: minus sign on the highest numerical digit)
Display frequency 1, 2, 5, 10 and 20 times/sec (selectable)
Scale capacity 5-digit numerical values
Minimum scale division/increment 1 to 50 (selectable)
Unit of measurement NONE, g, kg, t, or lb (selectable)
Decimal place 0, 0.0, 0.00, or 0.000 (selectable)
Over scale display LOAD (A/D converter input over),OFL1 (Net weight > Net over set value),OFL2 (Gross weight > Capacity +9 scale divisions),OFL3; (Gross weight > Gross over set value)
Center zero Display true zero point or the center of each value
Status display CLAMP, SP3, SP2, SP1, HOLD, COMPL., ZT, ZALM, STAB, TARE, NET, GROSS, NZ, D.CHG, HI, GO, LO, HI LIM, LO LIM, LOCK

 

Setting section
Setting method Can edited with using membrane switch.Setting can be performed by external devices as well via USB, RS-232C and RS-485 interface and so on.
Setting value memory Parameter, calibration and part of other settings are stored on NOV.RAM (non-volatile memory), and all other settings are stored on F.RAM (another non-volatile memory).
Setting value protection Overwrite protection by “LOCK” switch
Setting items Upper Limit/ Lower Limit/ Near Zero/ Set Point 1/ Set Point 2/ Compensation/ Over/ Under/ Final/ Comparison Inhibit Time/ Judging Time/ Complete Output Time/ Compensation Feeding Time/ Auto Free Fall Compensation Regulation/ Weighing Function 1/ Weighing Function 2/ Tare Setting/ Tare Display/ Digital Low Pass Filter/ Moving Average Filter/ Sample Speed/ Motion Detection (Period-Range)/ Zero Tracking (Period)/ Zero Tracking (Range)/ Weighing Function 3/ Key Invalid ・ Lock/ Error Output Selection/ Password/ Bag Clamp Output Time/ Discharging Time/ Weighing Start Time/ AZ Times/ Judging Times/ Sequence Mode 1/ Sequence Mode 2/ Extended Function Selection 1/ Extended Function Selection 2/ I/O Input Check/ I/O Output Check/ BCD Input Check/ BCD Output Check/ RS-485 Check/ Balance Weight Value/ Capacity/ Min Scale Division/ DZ Regulation Value/ Display Selection/ Gravitational Acceleration/ Net Over/ Gross Over/ RS-485 I/F Setting/ RS-485 Communication Type/ RS-485 ID/ RS-232C I/F Setting/ RS-232C Communication Type/ D/A Output Mode/ D/A Zero Output Weight/ D/A Full Scale Value/ BCD Data Update Rate/ Zero Calibration/ Span Calibration/ Equivalent Calibration/ Output Monitor Display/ Option Display

 

External signal
External output (16) Transistor open collector output.Isolation: photo coupler, Rated voltage: 30V, Maximum current: 120mA
External intput (22) The signal can be outputted by making short-circuit between input and common terminal.Isolation : photo coupler

 

Interface
USB USB interface
SIF 2-wire serial interface
232 RS-232C communication interface (option)
BCO BCD parallel data output interface (option)
DAC D/A converter interface (option)
485 RS-485 communication interface (option)
There is a option board slot only for RS-232C. Another option interface (only one option) can be installed as well.

 

General performance
Operating voltage AC100 to 240V (+10% -15%) [50/60Hz]
Rush current 2A, 1msec:AC100V average load condition (cold start at room temperature)4A, 1msec:AC200V average load condition (cold start at room temperature)
Power consumption Approx.18W
Operating conditions Operation temperature range: -10 to 40℃Storage temperature range: -20 to +85℃Humidity: 85%RH or less (non-condensing)
Dimensions 192(W)×96(H)×145(D) mm (Projections excluded)Panel cutout size: 186(W)×92(H) mm
Weight Approx. 1.7kg