Technical Information

Analog section
Excitation voltage DC5V±5% Output current:90mA
Remote sense type (Up to 6 350Ω load cells can be connected in parallel)
Signal input range -2.5 to +5.1mV/V
Zero adjustment range Automatic adjustment by digital processing -2.5 to +2.0mV/V
Span adjustment range

Automatic adjustment by digital processing 0.02 to +3.0mV/V

Linearization function Up to three point multi-point calibration is possible
Min. input sensitivity 0.15μV/count
Accuracy Non-linearity: within 0.01%FS
Zero drift: 0.0002%FS/℃ Typ
Gain drift: 1ppm/℃ Typ
Filter Digital low-pass filter 0.1 to 300.0 Hz
Moving average filter OFF, 2 to 512 times
A/D converter Speed: 300 times/sec., 1200 times/sec.
Resolution: 24bit binary
 
Display section
Display Unit 7-segment LCD display
Main display: 8 digit(14.4mm character height),
Sub-display: 20 digit (4.3mm character height)
Display value 5 digit sign: negative display at the highest digit (Up to 6 digits)
Unit None / kg / g / t / lb / N
Decimal point 0, 0.0, 0.00, 0.000
Weight errors “LOAD”: sensor signal level is above the signal input range,
“-LOAD”: the sensor signal level is below the signal input range,
“OFL1”: the Net weight is over the limit,
“OFL3”: the GROSS weight is over the limit
Display frequency 1, 3, 6, 13 or 25 times/sec.
Status display SP1 / SP2 / SP3 / COMPLETE / TARE ON / NET / OUT1 / OUT2
 
Setting section
Setting method By operating the membrane keys or through interface
Memory of set value Default settings: stored in NOV.RAM (non-volatile RAM)
Time: backed up by lithium battery
Other setting values: stored in F-RAM (non-volatile RAM)
Protection of set value Settings can be protected with the software LOCK
Setting item – Upper limit / Lower limit / Near zero / Set point 1 / Set point 2 / Compensation / Over / Under / Final
– Comparison inhibit time 1 / Judging time / Complete output time / Compensation Feeding Time / Number of times for AZ / Number of times for judging / Auto free fall compensation regulation values / Comparison inhibit time 2 / Preset tare value
– Weighing function 1 / Weighing function 2 / Weighing function 3 / Sequence mode / Key invalid-LOCK / Discharging Time / Motion detection(Period – Range) / Zero tracking (Period) / Zero tracking (Range)
– Balance weight value / Minimum scale division / NET weight over / GROSS weight over /DZ limitation value / Display selection / Gravitational acceleration / Sub-display mode /Sub-display selection
– D/A output mode / D/A zero scale adjustment / D/A full scale adjustment / RS-232C/RS-485 setting / RS-232C/RS-485 ID / Transmission delay time / CC-Link I/F setting / CC-Link station number setting / Setting LOCK
– Input Signal selection 1 / Input Signal selection 2 / Input Signal selection 3 / Output Signal selection 1 /Output Signal selection 2 / Output Signal selection 3 / Output Signal selection 4 / Status display selection / Sampling speed
– Total count / SP0 / Total comparison mode / Target total weight (high 4) /Target total weight (under 5) / Total SP1 (high 4) / Total SP1 (under 5)
– SD card command 1 / SD card command 2 / Time and Date / Auto adjustment filter / Digital low pass filter / Moving average filter / Extended function selection 1 / Extended function selection 2 / Total weight control function
– Average weight value / Maximum weight value / Minimum weight value /General standard deviation / Sample standard deviation / Number of data / Latest data /Maximum-Minimum / Option display
– Span calibration / Equivalent span calibration / Equivalent zero calibration / Linearize calibration 1 / Linearization calibration 2 / Linearization calibration 3 / Linearization Calibration / Calibration Point Confirmation / Password / Zero Calibration
 
External signal
Output signal (12) Selectable/configurable
Open collector output
Vceo=30V, Ic=120mA
Input signal (8) Selectable/configurable
Non-voltage contact input
(internal circuit power supply voltage 12V)
 
Interface
· SI/F interface
· SD card slot
· Select either RS-232C or RS-485 interface
· BCD parallel data output interface (Option)
· D/A converter current output (Option)
· CC-Link interface (option)
 
General performance
Power supply voltage AC100 to 240V (+10% -15%) (free power source 50/60Hz)
Power consumption 5W typ
Operating conditions Temperature Operating temperature range: -10 to +50℃
Storage temperature range: -20 to +60℃
Humidity 85%RH or less (non-condensing)
Dimensions 144(W)×72(H)×109(D)mm (excluding the projections)
Weight Approx. 850g