Technical Information

Analog section
Excitation voltage DC5V±5% Output current: within 90mA
Ratiometric method (Up to 6 load cells at 350Ω can be connected in parallel.)
Signal input range -0.3 to 3.0 mV/V
Zero adjustment range -0.2 to 3.0 mV/V Automatic adjustment by digital computation
Gain adjustment range Automatic adjustment by digital computation
Accuracy Non-linearity: within 0.01%/FS±1digit (when 3mV/V is input)
Zero drift: 0.025μV/℃ RTI Typ
Gain drift: 1ppm/℃ Typ
A/D converter Conversion rate: 1000 times/sec.
Resolution: 24bit (binary)
Min. display resolution 1/10000
Theoretical calibration Equivalent input calibration: accuracy when theoretical calibration is performed: 1/1,000
 
Filter
Digital filter Moving average (common for all modes): OFF, 2 to 999 times
Low-pass filter Variable: 2.0 to 10.0Hz
 
Display section
Display unit TFT color LCD module 3.5inch (320×240dot)
Display area: 71(W) x 53(H) mm
Weight display 5-digits (signs: minus sign on the highest numerical digit)
Unit NONE, kg, t, g, N, or lb (selectable)
Decimal place 0, 0.0, 0.00, or 0.000 (selectable)
Status display BUSY, GO, EMP, SMP, COMP, NZ, STAB
 
Setting section
Setting method Setting by analog touch panel operation (with a key click buzzer)
Setting can be performed by external devices as well via RS-232C interface and so on.
Setting value memory Initial values F.RAM (nonvolatile RAM), other values : lithium-battery-backed-up C-MOS RAM
Settings protection Setting operation can be prohibited to prevent changes by miss-operation (LOCK1, LOCK2, LOCK3).
Setting item ・Standard mode (COMP MODE SEL.: COMP):
 CODE/ STANDARD/ OVER/ UNDER/ UPPER/ LOWER
・Standard mode (COMP MODE SEL.: RANK.1):
 CODE/ BOUNDARY 0/ BOUNDARY 1/ BOUNDARY 2/ BOUNDARY 3/ UPPER/ LOWER
・Standard mode (COMP MODE SEL.: RANK.2):
CODE/ BOUNDARY 0/ BOUNDARY 1/ BOUNDARY 2/ BOUNDARY 3/ BOUNDARY 4/ BOUNDARY 5/ BOUNDARY 6/ BOUNDARY 7/ BOUNDARY 8/ BOUNDARY 9/ UPPER/ LOWER

・Checker mode:
CODE/ TAKING MODE/ TRIGGER MODE/ TAKING COUNT/ TAKING RATIO/ EMPTY COUNT/ NEAR ZERO/ DIGITAL LPF/ MOV. AVE. FILTER/ GROSS RATIO/ HISTOGRAM TARGET/ HISTOGRAM RANGE

・State output:
CODE/ OUTPUT SEL. 0/ OUTPUT SEL. 1*/ OUTPUT SEL. 2*/ OUTPUT SEL. 3*/ OUTPUT SEL. 4*
* Selectable from OUTPUT, COMP, NZ, TAKING, ERROR, LOWER, STAB, RUN

・Graph:
CODE/GRAPHIC MODE/TRIGGER LEVEL/X END POINT/Y START POINT/Y END POINT/DRAWING WEIGHT/ PRE TRIG.VALUE/FRONT OF FILTER

・Result:
CODE/ AVE.WEIGHT/ MAX.WEIGHT/ MIN.WEIGHT/ CNT.OF DATA/ GEN.STAN.DEV./ SMP.STAN.DEV./ MAX.-MIN./ LATEST DATA

・Comparison:
COMP MODE SEL./ STAND. CMP SEL./ COMPLETE OUT T./ NEAR ZERO COMP./ HI/LO COMP. SEL./ PRESET TARE WGT.1/ PRESET TARE WGT.2/ HOLD SELECT

・Operation:
MD (PERIOD)/ MD (RANGE)/ ZT (PERIOD)/ ZT (RANGE)/ INDICATE COLOR/ BACKLIGHT LOW TM/ BACKLIGHT ON TM/ AUTO ACCUMULAT./ OUTPUT MODE/ OUTPUT COMP. MODE/ WGT CODE INPUT/ ZT MODE/ AUTO ZERO AVE./ B4 FUNK. SELECT/ TAKING SPEED

・Communication:
COMM. MODE/ BAUD RATE/ LENGTH/ PARITY BIT/ STOP BIT/ TERMINATOR/ FLOW CONTROL/ SI/F OUT1 SELECT/ SI/F OUT2 SELECT

・System:
INITIALIZATION/ LOCK1/ LOCK2/ LOCK3/ PASSWORD/ LANGUAGE/ [GROSS/NET] KEY/ [DZ] KEY/ [TARE ON] KEY/ SELF CHECK DSP1/ SELFCHECK DSP2/ SELFCHECK MEM/ SELF CHECK KEY/ SELF CHECK EXT/ SELF CHECK COM

・Calibration:
ZERO CAL./ SPAN CAL./ EQUIV. CAL./ BALANCE WEIGHT/ MIN. SCALE DIV./ NET OVER/ GROSS OVER/ UNIT DISPLAY/ DECIMAL PLACE/DZ REGULATION VAL.

 
Total function
Histogram display Numbers of data for each 9 weight ranges are displayed. Two set of data out of the range are displayed as well.d>
Weighing results Results are displayed for each code.
Statistics Display statistics data stored on F650-CK.
Display average weight, maximum weight, minimum weight, number of data, population standard deviation, sample standard deviation, difference between maximum and minimum, latest data.
 
External signal
External output (10) OVER or RANK1 or RANK20/ GO or RANK2 or RANK21/ UNDER or RANK3 or RANK22/ NONE or RANK4 or RANK23/ NONE or RANK5 or STROBE/ OUTPUT SEL. 0/ OUTPUT SEL. 1/ OUTPUT SEL. 2/ OUTPUT SEL. 3/ OUTPUT SEL. 4
External input (10) CODE0/ CODE1/ CODE2 or KEY LOCK/ Graph drawing/ D/Z ON/ TARE ON/ TARE OFF/ Accumulation command/ Measurement start/ Measurement reset
 
Interface
SIF 2-wire serial interface
232 RS-232C communication interface
485 RS-485 communication interface (Modbus-RTU/ UNI-format) (option)
BCO BCD parallel data output interface (Sink type) (option)
BSC BCD parallel data output interface (Source type) (option)
DAV D/A converter(voltage output) (option)
DAI D/A converter(current output) (option)
ODN DeviceNet interface (option)
CCL CC-Link interface (option)
Only one option can be installed.
 
General performance
Operating voltage・Power consumption 100 to 240 Vac ±10 to 15% (50/60Hz) 18W max
Operating conditions Operation temperature range: -10 to +40℃
Storage temperature range: -20 to +60℃
Humidity: 80%RH or less (non-condensing)
Dimensions ・Weight 96(W)×96(H)×138(D)mm (Projections excluded)
Approx. 1.0kg